next up previous contents
Next: TSYS /CONTINUUM Up: NOEMA languages internal help Previous: SPW /LABEL   Contents


TSYS

        [NOEMAOFFLINE\]TSYS TableName

    Create the Tsys binary table used by the  NOEMA  sensitivity  estimator.
    None of the inputs can be customized at user level. Contents are:

    Code      C*4  [     ]  System code

    Pressure  R*4  [HPa  ]  Pressure at observatory altitude
    Gaini     R*4  [     ]  Image band gain
    IF        R*4  [GHZ  ]  Intermediate frequency

    Nf        I*4  [     ]  Number of frequencies
    Na        I*4  [     ]  Number of airmasses
    Nw        I*4  [     ]  Number of precipitable water vapor amounts
    Nt        I*4  [     ]  Number of temperatures

    F[Nf]     R*4  [GHz  ]  Frequencies
    A[Na]     R*4  [Neper]  Airmasses
    W[Nw]     R*4  [mm   ]  Precipitable water vapor amounts
    T[Nt]     R*4  [K    ]  Temperature values
    Trec[Nf]  R*4  [K    ]  Receiver temperatures (per frequency)
    Feff[Nf]  R*4  [     ]  Forward efficiencies (per frequency)

    Tsys[Nf,Na,Nw,Nt]  R*4  [K    ]  Tsys


Subsections

Gildas manager 2018-11-19