STORE AMPLITUDE

        CLIC\STORE AMPLITUDE [/BAND code] [/SELF]

    *** THIS HELP HAS NOT BEEN UPDATED FOR THE NGRX ***

    Store the amplitude calibration determined by the last SOLVE AMPLITUDE.

    One  calibration  curve is stored for each sideband.  With option "/BAND
    code", one may use the calibration curve  determined  with  one  of  the
    sidebands  (`code' is UPPER or USB, LOWER or LSB, or AVERAGE or DSB), to
    calibrate both sidebands.

    With option "/SELF", the calibration stored will not be the  calibration
    curve  (as  determined  from  the last SOLVE AMPLITUDE command) but, for
    each scan, the visibility corresponding to the first subband  set  (eg.,
    SET  SUB L01 to L03 ...); data from each side band will be used to cali-
    brate the same side band. This provide a simple, easy way to  self-cali-
    brate data taken on strong continuum sources (quasars).

    STORE  AMPLITUDE  and  STORE PHASE can be performed simultaneously using
    STORE AMPLITUDE PHASE [/BAND code] [/SELF] [/RECEIVER  irec]  (the  /RE-
    CEIVER option has no meaning for amplitudes).