Next: SET SCAN
Up: SET
Previous: SET REFERENCE
CLIC\SET RF_PASSBAND [ON|OFF] [CHANNEL|FREQUENCY]
[FILE|MEMORY] [ANTENNA|BASELINE]
ON|OFF : switch on or off the application of RF passband
calibration curve in plotting the data. The RF passband
calibration curve is solved for by SOLVE RF_PASSBAND and stored
with the data by STORE RF_PASSBAND. Subsequent PLOT commands
will use or not this curve according to the status of SET
RF_PASSBAND, which is displayed with the plot.
CHANNEL|FREQUENCY : use either the channel dependent passband
curves or the frequency dependent passband curve. The channel-
dependent passband curves must be determined separately for
each subband (continuum and spectral), while the frequency-
dependent passband curve is determined by using SOLVE RF_PASSBAND on
the continuum correlator, and is used for both the continuum and
spectral correlators (this will not work for data taken before July
14th 1990).
MEMORY|FILE : use either the passband curves just determined by
SOLVE RF_PASSBAND, and still [resent in the program memory, or
the passband curves previously stored in the data headers of the
input file by a previous command STORE RF_PASSBAND.
ANTENNA|BASELINE : Switch between Antenna-based and Baseline-based RF
passband calibrations. This switch will be active for SOLVE RF
(passband determination), STORE RF (passband store operation), and
SET RF ON (for passband application). Both baseline-based and
antenna-based calibration curves may be stored alongside in the data
header, independently of each other.