Next: SET COPY
Up: SET
Previous: SET WATER
CLIC\SET WEIGHTS [TSYS ON|OFF] [CALIBRATION ON|OFF]
Selects the way the data is weighted in command TABLE.
With TSYS ON, data is weighted by 1/TSYS**2, where TSYS is the
equivalent system temperature (the geometrical mean of system
temperature of both antennas, for a given baseline).
With TSYS OFF, this weight factor is turned off.
With CALIBRATION ON, data is also weighted by 1/CAL**2, where CAL is
the amplitude instrumental calibration factor (if any). If no
amplitude instrumental calibration function is applied (absolute
amplitude), this weighting should have no effect.
With CALIBRATION OFF, weights are not affected by amplitude
instrumental calibration.
With both TSYS OFF and CALIBRATION OFF, data is weighted
proportionally to observing time.
lucas@iram.fr