Next: SOLVE FLUX
Up: SOLVE
Previous: SOLVE BASELINE
CLIC\SOLVE DELAY [/SEARCH range interval] [/PLOT]
This uses a linear method to determine delays. The baselines to be
determined must have been selected by the SET BASELINE (or SET
ANTENNA) command, and the data plotted; plot axes must have been
previously selected by : SET X I_FREQUENCY and SET Y PHASE.
The results are given in nanoseconds.
The /SEARCH option enables an automatic search with starting
offsets from -range|2 to +range|2 by steps of given interval. the
default range is 200 nanoseconds, with interval of 1 nanosecond.
With SET ANTENNA in action the antenna delays are directly
fitted to the antenna phases, ensuring delay closure.
Use later command PRINT DELAY to create a procedure file (named CLIC-
DELAY.OBS) containing the fitted antenna delays. This procedure
file may be executed by the observing program OBS on the control
computer BURE01.
With option /PLOT, the fitted phases pill be plotted over the data.
lucas@iram.fr