CLIC\STORE PHASE [AMPLITUDE] [/BAND code] [/RECEIVER irec]
Store the phase (and optionally amplitude) calibration. Storing both
calibrations together is more efficient.
With option "/BAND code", one may use the calibration curve
determined with one of the sidebands (`code' is UPPER, LOWER or
AVERAGE), to calibrate both sidebands.
With option "/SELF", the calibration stored will not be the calibration
curve determined with the last SOLVE PHASE [or AMPLITUDE], but, for each
scan, the visibility corresponding to the first subband set (eg., SET
SUB L01 to L03 ...); data from each side band will be used to calibrate
the same side band. This provide a simple, easy way to calibrate data
taken on strong continuum sources (quasars).
With option "/RECEIVER irec", the calibration curves solved using data
from receiver "irec" will be stored in parallel with any other
calibration curve. This phase curve will be selected by giving SET
PHASE EXTERNAL. (see this command). This has no meaning for amplitudes.
/BAND may be used in conjunction with /RECEIVER.