Next: SHOW
Up: SET Language Help
Previous: PHASE
POINTING
SET\POINTING [IAZ Value] [IEL Value] [DVE Value] [DVN
Value] [IVE Value] [IVN Value] /ANTENNA Iant
Specify new (station dependent) pointing constants for antenna
Iant. The Station.Antenna file is updated. IAZ is the zero of azimuth,
IEL of elevation, IVE and IVN the inclinations from the
inclinometers, DVE and DVN offset from these inclinations. IVE and IVN
are normally determined by the INCLINOMETER procedure, while DVE and DVN
should be zero. Values can be arithmetic expressions, e.g. as in
command
SET\POINTING IEL IEL-6 IAZ IAZ+15 /ANT 3
1 RESTART
[SET\]RESTART [Program]
Restart a program. The program can be RDI, CORREL or AFF. This
command is typically used after a OBS\CANCEL STOP command, or when the
program died of unnatural causes (crash...).
By default, RESTART waits for end of observation. In case of
abnomalous death of RDI or CORREL, this may never happen. Pressing C
interrupts the wait state in this case. If OBS stills wait for start of
scan, you may have to type a CANCEL WAIT command to be able to restart.
Gildas manager
2002-02-04